DC voltage symbol (V⎓)
The DC voltage setting. A V with a solid line over three dashes (⎓) measures direct current volts; the line and dashes are the standard mark for direct current.
Easily confused with
How to read it
Fluke’s guide to the multimeter dial marks DC voltage ⎓ V and DC millivolts ⎓ mV, and Klein Tools and Extech list the same mark on their displays as DC, direct current. It is number 5031 in the IEC’s register of equipment symbols, which Philips’s symbol guide gives as equipment suitable for direct current only, and also uses to identify the relevant terminals. Unicode encodes it as ⎓, direct current symbol form two; form one is a single straight line, ⏤.
The mV position is the same measurement in thousandths of a volt (m is milli, 10⁻³, in Klein’s symbol list). On Fluke’s 114, 115 and 117 the DC voltage position reads from 0.001 V to 600 V and the mV position from 0.1 to 600 mV. A minus sign in front of the reading means negative polarity on Fluke’s, Klein’s and Extech’s meters.
Also searched as: ⎓, DC millivolts, DC volts symbol, direct current symbol, mV DC, VDC, V with a line and dashes, V with a straight line.
These pages describe what each setting, marking and reading means. They are not instructions for measuring anything. Meters differ between makers and models: the meter’s own manual says what each of its symbols means, which measurements it is rated for, and how to use it safely.
Look-alikes
A V with a wavy line is AC voltage. Some meters have one V position for both: Klein’s MM400 starts in AC and switches to DC with its SEL button, showing AC or DC on the display, and the Auto-V position on Fluke’s 114 and 117 selects AC or DC by itself from the input. The same line and dashes beside an A is DC current.
Read next
- Next in Multimeter symbolsAC voltage symbol (V~)The AC voltage setting. A V with a wavy line (V~) measures alternating current volts; the wave is the standard mark for alternating current.
- The same shape in Smoke and CO alarm soundsLow-frequency 520 Hz alarm (sleeping rooms)A fire alarm in a sleeping room that sounds a low buzz in place of a high-pitched beep. It is the three-beep fire alarm rhythm at 520 Hz, which NFPA 72 requires of alarms provided to wake people in sleeping areas.
More multimeter symbols
The same shape elsewhere
Browse symbols drawn with letters and numbers or lines.
Sources
- Multimeter Symbols, Buttons, Dials, and Display, Fluke learning centre article, Fluke Corporation, Digital multimeter dial
- 114, 115, and 117 True-rms Multimeters: Users Manual, PN 2572573, July 2006, Rev. 1, 2/07, Fluke Corporation (copy hosted by UCL Electronic and Electrical Engineering), Display; Rotary switch positions
- MM400 Auto-Ranging Digital Multimeter: Instruction Manual, MM400 instruction manual, Klein Tools (copy hosted by UBC Earth, Ocean and Atmospheric Sciences), Symbols on LCD; Operating instructions, AC/DC voltage
- Mini Multimeter with Non-Contact Voltage Detector, Model EX330: User’s Guide, EX330-EU-ENG V4.2 1/08, Extech Instruments (copy hosted by Core Electronics), Display symbols and annunciators; General specifications
- Electricity and electronics symbols, Philips symbol glossary (IEC 60417 / IEC 60878 graphical symbols), Philips, IEC 60878 5031
- Miscellaneous Technical, Range: 2300–23FF (code chart), The Unicode Standard, Unicode Consortium, U+2393 and U+23E4
Researched, edited and approved by Rory Hansen before publishing. Last reviewed October 9, 2026. How we research
Added .