Chirp every 30 to 60 seconds (smoke or CO alarm)

The alarm reporting on itself, not on smoke or carbon monoxide: most often a low battery, and on some alarms the end of the alarm’s working life.

The pattern One short chirp, then silence for 30 to 60 seconds before the next. The clip plays one chirp.

Synthesised from makers’ descriptions; real alarms are much louder and the pitch varies by model. A synthesised clip, not a recording. The sound alone (WAV)

Easily confused with

How to read it

A chirp is one short sound, repeated every 30 to 60 seconds, where an alarm for smoke or carbon monoxide is a repeating set of beeps. On the smoke alarm CPSC staff examined, the low-battery signal to the horn was a pulse about 10 milliseconds wide. No standard sets the chirp: each maker sets its own, and the alarm’s manual lists them. NFPA’s Fire Prevention Week tip sheet gives the common reading: a single chirp every 30 or 60 seconds means the battery is low, and chirping that continues after the battery has been replaced means the alarm is at the end of its life. CO alarms also have end-of-life sounds that vary by manufacturer, the tip sheet says.

Also searched as: co detector chirping, end of life chirp, low battery chirp, smoke alarm chirp, smoke detector beeping every 30 seconds, smoke detector chirping.

These describe what each alarm sound means and which standard sets it. Sounds differ between makers and models, and the alarm’s own manual lists what each of its sounds means. What to do when an alarm sounds is set out by the US Fire Administration at usfa.fema.gov and by your local fire department.

What each maker’s chirps mean

AlarmLow batteryEnd of lifeOther chirps
Kidde smoke alarmsA chirp every 30 to 40 seconds (every 60 on some) for at least seven daysSealed-battery models: a chirp every 30 secondsHush: a chirp every 30 to 40 seconds for about seven minutes
Kidde CO alarmsA chirp once every 60 secondsA chirp every 30 seconds, from seven years after first power-upNot given
BRK CO and combination alarmsNot given5 chirps, after about 120 months (60 or 72 on some models)Not given
Gentex S1209 smoke alarm1 chirpNot given2 chirps: silenced for smoke, or a trouble condition
Gentex CO1209 CO alarm1 chirp with an LED flash3 chirps with an LED flash2 chirps with an LED flash: dirty or defective, or a large influx of CO

Kidde’s sealed-battery smoke alarms and its CO alarms chirp every 30 seconds at the end of their life, the same interval Kidde gives for some low-battery chirps. BRK says its end-of-life chirp can be silenced for about 2 days at a time, and after about 2 to 3 weeks can’t be silenced.

The clip on this page

It plays one chirp of 10 milliseconds at 3.2 kHz, the frequency CPSC staff measured on a smoke alarm’s horn; a real alarm repeats it every 30 to 60 seconds. UL 217 sets no frequency for the horn, so a real chirp may sound higher or lower.

More smoke and CO alarm sounds

The same shape elsewhere

Sources