Three beeps and a pause (smoke alarm)
A smoke or fire alarm sounding for smoke or fire. Three beeps and a pause, repeating, is the temporal-3 pattern, the standard emergency evacuation signal.
The pattern Beep, beep, beep, pause; repeating. Each beep and each gap between beeps lasts half a second, and the pause after the third beep lasts 1.5 seconds. The pattern repeats every 4 seconds.
Synthesised from the standard’s timing; real alarms are much louder and the pitch varies by model. A synthesised clip, not a recording. The sound alone (WAV)
Easily confused with
- Four beeps and a pause (carbon monoxide alarm)Four short beeps and a 5-second pause, where smoke is three half-second beeps and a 1.5-second pause.
- Chirp every 30 to 60 seconds (smoke or CO alarm)The alarm reporting on itself, not on smoke or carbon monoxide: most often a low battery, and on some alarms the end of the alarm’s working life.
How to read it
The pattern is called temporal-3, or T3. Each beep lasts half a second, with half a second between beeps, and after the third beep there are 1.5 seconds of silence before the next three, so the pattern repeats every 4 seconds. NFPA 72 allows each part 10 percent either way. ANSI S3.41 and ISO 8201 define it as the audible emergency evacuation signal, and UL 217, the standard smoke alarms are tested to, requires a smoke alarm, or a combined smoke and carbon monoxide alarm, to sound it when it detects smoke. Gentex’s manual for its S1209 smoke alarm puts it as “3 beeps, a pause, 3 beeps, a pause”, and NFPA’s Fire Prevention Week tip sheet says three loud beeps mean smoke or fire. The carbon monoxide pattern has four shorter beeps and a longer pause.
Also searched as: fire alarm sound, smoke alarm three beeps, smoke detector beeping 3 times, t3 alarm, temporal 3 pattern, three beeps smoke detector.
These describe what each alarm sound means and which standard sets it. Sounds differ between makers and models, and the alarm’s own manual lists what each of its sounds means. What to do when an alarm sounds is set out by the US Fire Administration at usfa.fema.gov and by your local fire department.
Smoke alarms and building fire alarms
A building’s fire alarm system sounds the same rhythm. NFPA 72 requires it wherever the intended response is to evacuate the building, as Gentex’s manual quotes the code, and New York City’s building code requires it of new fire alarm systems in buildings whose fire safety plan is a total evacuation, the FDNY says. The pattern is the rhythm, not the sound: the FDNY notes that bells, horns or speakers can all sound it.
The pitch of the beeps
No standard sets it. CPSC staff found no requirement in UL 217 for the frequency of a smoke alarm’s horn and say a typical one sounds between 3,000 and 4,000 Hz; the alarm they tested sounded at 3.2 kHz. UL 217 sets the loudness instead: at least 85 dBA, 10 feet from the horn. The clip on this page is synthesised at 3.2 kHz from the standard’s timing, and plays far more quietly. A real alarm may sound higher or lower; the rhythm is what identifies it.
Read next
- Next in Smoke and CO alarm soundsFour beeps and a pause (carbon monoxide alarm)A carbon monoxide alarm sounding for carbon monoxide. Four short beeps and a pause of about 5 seconds, repeating, is the temporal-4 pattern, the standard signal for carbon monoxide.
- The floor-plan symbol for where a smoke detector goes.Smoke detectorMarks where a smoke detector is installed. Drawings use more than one symbol for it, so the legend says which is meant.
More smoke and CO alarm sounds
The same shape elsewhere
Browse symbols drawn with lines.
Sources
- S1209 Series Photoelectric Smoke Alarm: Installation Instructions and Owner’s Manual, S1209 owner’s manual, Gentex Corporation, models; checkout; temporal 3 activation signal
- Possible Technologies for Improving the Audibility of Residential Smoke Alarms, CPSC-ES-0505 (September 2005), U.S. Consumer Product Safety Commission, §2.3 and Figure 5 (“Three Pulse” Temporal Pattern)
- The Audibility of Smoke Alarms in Residential Homes, CPSC-ES-0503 (September 2005), U.S. Consumer Product Safety Commission, §3.2 Smoke Alarm Signal; Figure 3
- Carbon Monoxide Alarm Considerations for Code Authorities, UL 2034 and UL 217, UL Solutions, CO alarm signal
- Fire Alarm Inspection Unit Information Bulletin No. 01-03-12: Modification of Fire Alarm Signaling, FDNY bulletin 01-03-12 (March 22, 2012), New York City Fire Department (FDNY), Purpose
- Learn the Sounds of Fire Safety: Fire Prevention Week tip sheet, Fire Prevention Week 2021, ©2021 NFPA, National Fire Protection Association (copy published by Bloomfield Township, Michigan), Smoke alarms
Researched, edited and approved by Rory Hansen before publishing. Last reviewed October 9, 2026. How we research
Added .